![]() |
0.000 | 0.015 | 0.040 | |
![]() |
350 | 650 | 1150 | [MPa] |
QY: | 0 | 300 | 800 | [MPa] |
Reloading the bar to 350 MPa the hysteresis loop closes and the cycle
will stabilize.
Loading |
![]() |
![]() |
H |
![]() |
![]() |
0 | 0 | 0 | 350 | -350 | 350 |
+400 | 50 |
![]() |
350 | -300 | 400 |
-400 | 100 |
![]() |
350 | -400 | 300 |
+400 | 100 |
![]() |
350 | -300 | 400 |
-400 | 100 |
![]() |
350 | -400 | 300 |
+400 | 100 |
![]() |
350 | -300 | 400 |
-400 | 100 |
![]() |
350 | -400 | 300 |