Imaging facility of IEB AS CR
Equipment
Inverted laser scanning microscope (2015) | |
Illumination | HXP120 V Illuminator/HAL 100 |
Confocal lasers: diode laser (405nm-30), Argon ion laser (458, 488, 514nm), DPSS laser (561nm-10), HeNe laser(633nm) | |
Objectives | Plan-Apochromat 5x/0.16 M27 |
Plan-Apochromat 10x/0.45 DIC M27 | |
Plan-Apochromat 20x/0.8 DIC M27 | |
C-Apochromat 10x/0.45 W DIC M27 | |
C-Apochromat 40x/1.2 W Kor FCS M27 | |
Plan-Apochromat 63x/1.40 Oil DIC M27 | |
Fluorescence filtercubes | FS49/ DAPI (Ex 365 Em BP 445/50) |
FS38/GFP BP (Ex 470/40 Em BP 525/50) | |
FS63 HE/mRFP (Ex BP 572/25 Em BP 629/62) | |
Confocal laser scanning head | Zeiss LSM880 laser scanning microscope (Axio Observer Z1, inverted) with Definite Focus. System is equipped with high sensitivity spectral GaAsP photodetector, two PMT detectors for confocal, one PMT for transmitted light. All scanners are able to performe bidirectional scanning. Capabilities for FCS, RICS, FRAP, FRET and High Dynamic Range (HDR) applications. |
Signal detection | 1x spectral high sensitive GaAsP photodetector, 2x standard PMT detectors for confocal; one PMT for transmitted light (T-PMT) |
Additional equipment | Definite Focus - focal drift compensation, active anti-vibration table |
Software | ZEN black with Experiment Designer, 3D, Tiles, FRAP, FRET, FCS, HDR Analysis modules |
Location | building B1 room 008 |
Phone | ext. 830 |
Reservation | http://www.ueb.cas.cz/if |
Inverted laser scanning microscope (2006) | |
Illumination | X-cite series 120 Illuminator/HAL 100 |
Confocal lasers: diode laser (405nm-50); Argon ion laser (458, 477, 488, 514nm); diode laser 488-100 (LIVE); DPSS laser (532nm-75); DPSS laser (561nm-10); HeNe laser(630nm); diode laser 635-35 (LIVE) | |
Objectives | EC Plan-Neofluar 5x/0.15 |
EC Plan-Neofluar 10x/0.30 M27 | |
Plan-Apochromat 20x/0.8 DIC M27 | |
C-Apochromat 40x/1.2 W Corr FCS DIC M27 | |
Plan-Apochromat 63x/1.40 Oil DIC M27 (moved to ApoTome2 microscope) | |
LCI Plan-Neofluar 63x/1.3 Im Korr DIC | |
Fluorescence filtercubes | FS49 DAPI, Hoechst (Ex 365 Em BP 445/50) |
FS38/GFP, FITC BP (Ex 470/40 Em BP 525/50) | |
FS20/Rhodamine, TRITC, mOrange (EX BP 546/12 EM BP 575-640) | |
Confocal laser scanning head | Zeiss LSM 5 Duo laser scanning confocal microscope (Axiovert 200, inverted) equipped with fast LIVE 5 line-scanner with one CCD detector and spectral LSM510 point scanner PMT detector and two other single point PMT detectors. The setup allows all applications of point and line laser scanning (x, y, xy, xyz, xyt, xyzt, xyλ) including FRAP, FRET and ratiometric measurements. |
Signal detection | 1x CCD detector (LIVE), 1x spectral single point PMT detector, 2x single point PMT detectors, one PMT for transmitted light (T-PMT) |
Additional equipment | LaCon POC-R-cell cultivation system with peristaltic pump and heating block |
Software | LSM Image Examiner with Tiles / Positions, FRAP, FRET modules |
Location | building B1 room 009 |
Phone | ext. 474 |
Reservation | http://www.ueb.cas.cz/if |
Inverted SD microscope (2014) | |
Illumination | X-cite 120 PC Q Illuminator/HAL 100 |
Agilent Laser Box MLC400: 405, 488, 561, 640 nm. Laser power 20mW each laser line. | |
Objectives | Plan-Apochromat L 4x/0.2 |
Plan-Apochromat L 10x/0.45 | |
Plan-Apochromat L 20x/0.75 | |
Plan-Apochromat LS 40x/1.25 WI | |
Plan-Apochromat L 100x/1.45 Oil | |
Plan-Apochromat VC 60x/1.2 W | |
Plan-Apochromat L 60x/1.40 Oil - not mounted | |
Fluorescence filtercubes | Quadruple band filter set (390/482/563/640 nm) |
Semrock brightline Em 447/60 | |
Semrock brightline Em 525/30 | |
Semrock brightline Em 542/27 | |
Semrock brightline Em 607/36 | |
Semrock brightline Em 685/40 | |
Confocal laser scanning head | Spinning disc microscope Nikon (Eclipse Ti-E, inverted) with Yokogawa CSU-X1 SD unit, high speed filter wheel unit and dual camera system. Microscope is equipped with perfect focus system, Prior motorized stage with z-Piezo, ultra-sensitive EM CCD camera Andor iXon3 897 and Andor Zyla high resolution sCMOS camera. The setup allows sequential or parallel recording of signal in xy, xyt, xyz and xyzt with one or two cameras and FRET measurements. |
Signal detection | EM CCD iXON3 897 Andor, 512x512, QE 92%, 34 fps, pixel size 16 mm, Peltier cooling; sCMOS ZYLA Andor, 2560x2160 pixel, QE 57%, 30fps, pixel size 6.5 mm |
Additional equipment | Perfect Focus System - focal drift compensation; active anti-vibration table |
Software | NIS Elements |
Location | building B1 room 009 |
Phone | ext. 474 |
Reservation | http://www.ueb.cas.cz/if |
Upright widefield epifluorescence microscope with optical sectioning using structured illumination (2015) | |
Illumination | HXP120 V Illuminator/VIS LED |
Objectives | EC Plan-Neofluar 10x/0.3 M27 |
EC Plan-Neofluar 20x/0.50 DIC M27 | |
C-Apochromat 40x/1.2 W Kor DIC M27 | |
Plan-Apochromat 63x/1.40 Oil DIC M27 (moved to ApoTome2 microscope) | |
Plan-Apochromat 100x/1.40 Oil DIC M27 | |
Fluorescence filtercubes | FS01/DAPI (Ex BP365/12 Em LP 397) |
FS47/CFP (Ex BP 436/20 Em BP 480/40) | |
FS09/GFP LP 515nm (Ex BP 450-490 Em LP 515) | |
FS38/GFP BP (Ex 470/40 Em BP 525/50) | |
FS43/CY3, Rhodamine, mOrange (Ex BP 545/25 Em BP 605/70) | |
FS63 HE/mRFP (Ex BP 572/25 Em BP 629/62) | |
FS25 TRIPLE band/CFP+GFP+mRFP (Ex TBP 400 + 495 + 570 Em TBP 460 + 530 + 625) | |
Confocal laser scanning head | Upright Zeiss AxioImager Z2 Epifluorescence / Widefield Microscope equipped with ApoTome2 module for optical sectionning using structured illumination. Suitable for general-purpose transmitted light and fluorescence widefield microscopy as well as for the imaging with ApoTome2 structured illumination. Fully motorized. |
Signal detection | CCD Axiocam 506 mono (6Mpix (2752x2208), 19 fps, pixel size 4.5 mm; CMOS Axiocam 105 color (5Mpix) |
Additional equipment | ApoTome 2; anti-vibration table |
Software | Zen pro with Deconvolution Module |
Location | building B1 room 008 |
Phone | ext. 830 |
Reservation | http://www.ueb.cas.cz/if |
2012 | |
Location | building B2 basement room |
Reservation | http://www.ueb.cas.cz/if |
2008 | |
Confocal laser scanning head | Automated pipetting station for in situ hybridizations and immunohistochemical methods. This machine can be used for stainings of both whole mounts and sections on slides. Size of incubation baskets is suitable for Arabidopsis thaliana seedlings and many other materials. Simultaneous incubation of 60samples (objects or slides) is possible with optional cooling or heating of incubation buffers and incubation area. It is possible to recover washing solutions (e.g. antibodies) and use them repeatedly. |
Location | building B1, 2nd floor, room 216 |
Phone | ext 435 |
Reservation | http://www.ueb.cas.cz/if |
LaCon POC-R-cell cultivation system with peristaltic pump and heating block (chamber)
LaCon POC-R-cell cultivation system with peristaltic pump and heating block (heating block)
LaCon POC-R-cell cultivation system with peristaltic pump and heating block (pump)No info...