AB SCIEX TripleTOF™ 5600 with Dionex ULTIMATE 3000 HPLC system
Location: |
Department of Mass Spectrometry |
Responsible person: |
Dr. Josef Cvačka (phone 220 183 303) |
The AB SCIEX TripleTOF 5600 is the next generation in Quadrupole TOF technology. Starting with the best-in-class Triple Quad 5500 System, the new AcceleratorTOF Analyzer
was developed to add high-resolution at the speed and sensitivity needed to give equivalent CV's and limits of quantitation (LOQ) to high-end triple quadrupoles. The mass
spectrometers uniquely integrates comprehensive qualitative exploration, rapid profiling, and high-resolution quantitation workflows on a single platform. It combines the highest
sensitivity detection, high-resolution with 100 Hz acquisition speed, and stable ~1 ppm mass accuracy over days of acquisition. The spectrometer is connected with Dionex ULTIMATE
3000 HPLC system. The instrument was installed in summer 2011.
LTQ Orbitrap XL
Location: |
Department of Mass Spectrometry |
Responsible person: |
Dr. Vladimír Vrkoslav (phone 220 183 461) |
LTQ Orbitrap XL (Thermo Fisher Scientific) is a hybrid FT mass spectrometer combines a linear ion trap MS and the Orbitrap mass analyzer.
Ions generated by API (APCI, ESI, nanoESI) are collected in the LTQ XL followed by axial ejection to the C-shaped storage trap which is used to store and
collisionally cool ions before injection into the orbitral trap. The ions transferred from the C-Trap are captured in the orbitral trap by rapidly increasing
the electric field and the detection of the image current from coherent ion packets takes place after the voltages have stabilized. Signals from each of the
orbitral trap outer electrodes are amplified and transformed into a frequency spectrum by fast Fourier transformation which is finally converted into a mass spectrum.
Dynamic range up tu 2000 u, excelent mass accuracy (better then 5 ppm), fast cycle times for MS/MS experiments and high sensitivity are features of this instrument.
LTQ Orbitrap XL can be coupled to UHPLC system for LC/MS applications. This instrument was installed in January 2008.
Q-Tof micro
Location: |
Department of Mass Spectrometry |
Responsible person: |
Dr. Josef Cvačka (phone 220 183 303) |
Q-Tof micro (Waters) is a quadrupole orthogonal acceleration time-of-flight tandem mass spectrometer that enables exact mass measurement in both MS and MS/MS modes of analysis.
ESI, nano-ESI and APCI ion sources are available. Q-Tof micro is coupled to CapLC capillary HPLC for tryptic digest separations. The instrument was installed in 2004.
SYNAPT G2
Location: |
Department of Mass Spectrometry |
Responsible person: |
Dr. Martin Hubálek (phone 220 183 117) |
The Waters SYNAPT G2 is an ion-mobility mass spectrometer which allows to separate gaseous ions not only in terms of mass,
but also in terms of their shapes. This innovative technology been commercialized only few years ago and so far (status 2012),
there are only 3 machines of this type in CR.
Parameters
instrument type: tandem mass spectrometer with ion-mobility separation
ionization method: electrospray ionization
mass range: from m/z 10 up to m/z 4000
resolution: m/dm = ca. 20000 in standard operation shape - better than ever before allowing scientists to identify sample components that might have remained invisible to them until now.
2× Thermoquest TSQ
Location: |
Department of Mass Spectrometry |
Responsible person: |
Dr. Josef Cvačka (phone 220 183 303) |
Two TSQ (ThermoFisher Scientific) triple quadrupole tandem mass spectrometers for ion-reactivity studies. Specialized inlet
systems allow the introduction of various samples in the ionization as well as the reaction regions.
Parameters
instrument type: tandem mass spectrometer with triple quadrupole configuration
ionization methods: electron ionization, chemical ionization, electrospray ionization, atmospheric pressure chemical ionization
mass range: from m/z 2 up to m/z 3200
ultrafleXtreme™
Location: |
Department of Mass Spectrometry |
Responsible person: |
Dr. Josef Cvačka (phone 220 183 303) |
UltrafleXtreme™MALDI-TOF/TOF mass spectrometer (Bruker Daltonics, Germany) is the only instrument combining true 1 kHz smartbeam II laser technology speed
in both TOF and TOF/TOF modes with ultra-high performance and extreme flexibility. The instrument was installed in 2011.
|