HomeInstrumentationCapillary Electrophoresis

Capillary Electrophoresis


Automated capillary electrophoretic analyzer Agilent 7100

Location:   Department of Electromigration Methods
Responsible person:   Dr. Dušan Koval (phone 220 183 546)

Agilent 7100


Agilent 7100 CE analyzer allows to perform all modes of capillary electromigration techniques: zone electrophoresis, isotachophoresis, isoelectric focusing, affinity electrophoresis, electrokinetic chromatography and electrochromatography. Detector: spectrophotometric diode array detector (190-600 nm). Injection system: automatic hydrodynamic or electrokinetic. Separation compartment: fused silica capillary, id/od 25-100/360 µm, total/effective length 30-100/20-90 cm; capillary is placed in the cartridge with liquid thermostatization at 10-60 °C.


Capillary electrophoretic analyzer Beckman Coulter P/ACE MDQ

Location:   Department of Electromigration Methods
Responsible person:   Dr. Dušan Koval (phone 220 183 546)

P/ACE MDQ


P/ACE analyzer allows to perform all basic modes of capillary electromigration techniques, zone electrophoresis, isotachophoresis, isoelectric focusing, affinity electrophoresis, electrokinetic chromatography and electrochromatography. Detectors: diode array spectrophotometric detector (190-600 nm) and laser induced fluorescence detector, excitation/emission (488/520 nm).


Capillary electrophoretic analyzer Villa-Labeco EA 101

Location:   Department of Electromigration Methods
Responsible person:   Dr. Dušan Koval (phone 220 183 546)

EA 101


EA 101 analyzer allows to perform several modes of capillary electromigration techniques both in one- and two dimensional arrangement on both preseparation and analytical column. Detectors: contactless conductivity detectors on both columns and UV-VIS spectrophotometric detector (190-600 nm) on analytical column.


Capillary electrokinetic analyzer CE 2

Location:   Department of Electromigration Methods
Responsible person:   Dr. Dušan Koval (phone 220 183 546)


CE 2 is IOCB home-made device a manually operated analyzer with PC-based data acquisition and evaluation (Clarity station, Dataapex, Prague, CR). It allows to perform all basic modes of capillary electromigration techniques: zone electrophoresis, isotachophoresis, isoelectric focusing, affinity electrophoresis, electrokinetic chromatography and electrochromatography. Detectors: home-made photometric detector operating at fixed wavelength 206 nm (high-frequency excited electrodeless discharge lamp, interference filter, Si-photodiode).


Continuous free-flow electrophoresis FFE1

Location:   Department of Electromigration Methods
Responsible person:   Dr. Dušan Koval (phone 220 183 546)


FFE1 is IOCB home-made device allowing to perform all separation modes of electromigration methods in a free solution in the continuous flow-through arrangement with the preparative capacity of 50-100 mg of substance per hour.


Continuous free-flow electrophoresis Weber Octopus

Location:   Department of Electromigration Methods
Responsible person:   Dr. Dušan Koval (phone 220 183 546)

FFE Weber


FFE1 Octopus allows to perform all separation modes of electromigration methods in a free solution in the continuous flow-through arrangement with the preparative capacity of 50-100 mg of substance per hour.