Shared Equipment
For equipment booking use our on-line reservation system (requires registration).
Microscopy facility
Equipment | Year | Dept | Location | Use for | Manager | Operator | |
---|---|---|---|---|---|---|---|
Leica SP2 AOBS | 2007 | 60 | DAI 9 | Inverted laser scanning and fluorescence microscope | Chernyavskiy Oleksandr PhD. | ||
Leica SP8 AOBS WLL MP confocal | 2015 | 60 | DAI 10 | Inverted laser scanning and multiphoton microscope | Chernyavskiy Oleksandr PhD. | ||
Leica SPE confocal | 2007 | 60 | DAI 9 | Upright laser scanning and fluorescence microscope | Chernyavskiy Oleksandr PhD. | ||
Optical projection tomography | 2011 | 60 | DAI 13 | 3D imaging of transparent samples | Radochová Barbora, RNDr., Ph.D. | ||
CellVizio Optic fibre confocal microscopy | 2015 | 33 | D 050 | Optic fibre confocal microscope capable of fluorescence imaging from surface to deep tissues in whole animal. See more. | Otáhal Jakub doc. MUDr. PhD | ||
Neuroimage - stereology microscope | 2010 | 33 | D 048 | Neuroimage (MBF Bioscience) | Kubová Hana doc. Dr. DrSc. | ||
Leica LMD 6000 Laser capture microdissector | 2008 | 21 | D 239 | Allows to identify and dissect microareas from tissue or cell smear. | Martin Vodička Mgr. | ||
Carv II system | 2013 | 32 | D 048 | Spinning disc confocal microscope | Kubík Štěpán, RNDr. PhD. |
Proteomic facility
For more information, you can also directly check the ProteoLab website.
Equipment | Year | Dept | Location | Use for | Manager | Operator | |
---|---|---|---|---|---|---|---|
Mass spectrometer | 2005 | 22 | E 305 | HPLC and mass spectrometry analysis of physiologically important compounds | Mikšík Ivan prof. Ing. DrSc. | ||
Capillary electrophoresis Agilent 7100 | 2012 | 22 | E 201 | Separation instrument for analysis of a broad spectrum of compounds | Mikšík Ivan prof. Ing. DrSc. | Mgr. Pavla Sedláková, PhD | |
2D electrophoresis and Bruker MaXis MS | 2009 | 22 | E 306 | Proteomic analysis | Mikšík Ivan prof. Ing. DrSc. | Ing. Statis Pataridis |
Metabolomic facility
Equipment | Year | Dept | Location | Use for | Manager | Operator | |
---|---|---|---|---|---|---|---|
Qtrap 5500 mass spectrometer | 2012 | 17 | E 218 | metabolomics, lipidomics | Kuda Ondřej RNDr. Ph.D. | Ivana Brabcová, Ph.D. | |
|
CentriVap Refrigerated Vacuum Concentrator | 2016 | 17 | E 218 | metabolomics | Kuda Ondřej RNDr. Ph.D. |
Whole body phenotyping
Equipment | Year | Dept | Location | Use for | Manager | Operator | |
---|---|---|---|---|---|---|---|
Behavioral analysis |
|||||||
PhenoWorld - automatic modular system | 2015 | 32 | G | Modular system for complex behavioral analyses | Kubík Štěpán, RNDr. PhD. | ||
Multi conditioning system | 2011 | 32 | D 037 | System accommodating nine standard conditioning paradigms for the evaluation of learning, memory, emotion and stress-related behaviors in mice and rats. | Valeš Karel RNDr. Ph.D. | ||
Phenotyper - system for behavioral analysis | 2013 | 33 | D 011 | PhenoTyper (Noldus) for 8 rats. System is designed for automatated behavioral analysis in instrumented observation cage. | Kubová Hana doc. Dr. DrSc. | ||
2016 | 41 | E 017 |
Analytical Instrument to determine haematological parameters from whole blood |
RNDr. Světlana. Žufanová | |||
CT/PET |
|||||||
microCT/PET Albira | 2012 | 96 | G 145 | In vivo imaging of small laboratory animals | Flachs Pavel RNDr. Ph.D. | Dammer Jiří Mgr. | |
Echocardiography |
|||||||
GE-VIVID 7 echocardiography | 2010 | 80 | D302b | Non-invasive assessment of heart geometry and function | Papoušek František Ing. CSc. | ||
Blood pressure |
|||||||
Telemetric monitoring of blood pressure | 2013 | 25 | D | Long term telemetric monitoring of blood pressure and sympathetic activity | Vaněčková Ivana RNDr. CSc. | ||
Metabolism |
|||||||
Indirect calorimetry INCA Somedic | 2012 | 17 | G 008 | Indirect calorimetry for mice and rats | Kristína Bardová Mgr. |
Mitochondrial energetics
Equipment | Year | Dept | Location | Use for | Manager | Operator | |
---|---|---|---|---|---|---|---|
Oroboros Oxygraph 2k | 2013 | 13+17 | DAII 108 | Three setups for measurement of cellular/mitochondrial respiration. One with fluorescent attachment for ROS/ATP monitoring | Pecina Petr, Mgr. PhD | ||
Seahorse Xfe-24 alanyzer | 2014 | 13 | DAII 228 | Plate based system for measurement of respiration and glycolytic activity of cells | Mráček Tomáš, RNDr. PhD |
Molecular biology facility
Equipment | Year | Dept | Location | Use for | Manager | Operator | |
---|---|---|---|---|---|---|---|
Agilent RNA analyzer | 2004 | 21 | D 224 | Provides sizing, quantitation and quality control of DNA, RNA, proteins and cells on a single platform. | Ergang Peter Ing. PhD | ||
Nanodrop spectrophotometer | 2007 | 21 | D 224 | Measurement of nucleic acid concentration and purity and fluorescent dye labeled proteins. | Ergang Peter Ing. PhD | ||
Light Cycler 480 real-time PCR | 2009 | 17 | D 224 | Real-time PCR system | Flachs Pavel RNDr. Ph.D. | ||
ViiA 7 real-time PCR | 2012 | 21 | D 224 | Real-time PCR system with HRM possibility | Ergang Peter Ing. PhD |
Plate-readers
Equipment
|
Year | Dept | Location | Use for | Manager | Operator | |
---|---|---|---|---|---|---|---|
Microbeta counter | 2004 | 14 | D 121 | scintillation counting in a plate format | Doležal Vladimír MUDr. DrSc | ||
Reader Tecan infinity M200 | 2007 | 13 | DAII 112 | Luminescence, Fluorescence (top reading), UV-absorbance (UV-VIS) plate-reader with injectors | Mráček Tomáš, RNDr. PhD | ||
Reader Victor X4 | 2011 | 14 | D 121 | Luminescence, Fluorescence Intensity (both top and bottom reading), UV-absorbance (UV-VIS) and Time-Resolved Fluorescence technologies | Doležal Vladimír MUDr. DrSc | ||
Reader Synergy HT | 2008 | 16 | D 324 | single-channel absorbance, fluorescence (400/30, 460/40, 485/20, 508/20, 516/20, 528/20, 560/15, 590/20) and luminiscence microplate reader. | Zimmermannová Olga Ing. PhD |