Volume 47, Issue 23 ee2020GL090593
Research Letter

Two Propagation Scenarios of Isolated Breakdown Lightning Processes in Failed Negative Cloud‐to‐Ground Flashes

Ivana Kolmašová

Corresponding Author

Department of Space Physics, Institute of Atmospheric Physics of the Czech Academy of Sciences, Prague, Czechia

Faculty of Mathematics and Physics, Charles University, Prague, Czechia

Correspondence to:

I. Kolmašová,

iko@ufa.cas.cz

Search for more papers by this author
Ondřej Santolík

Department of Space Physics, Institute of Atmospheric Physics of the Czech Academy of Sciences, Prague, Czechia

Faculty of Mathematics and Physics, Charles University, Prague, Czechia

Search for more papers by this author
Eric Defer

Laboratoire d'Aérologie, Université de Toulouse, CNRS, OMP, UPS, Toulouse, France

Search for more papers by this author
Petr Kašpar

Department of Space Physics, Institute of Atmospheric Physics of the Czech Academy of Sciences, Prague, Czechia

Search for more papers by this author
Andrea Kolínská

Department of Space Physics, Institute of Atmospheric Physics of the Czech Academy of Sciences, Prague, Czechia

Faculty of Nuclear Sciences and Physical Engineering, Czech Technical University, Prague, Czech Republic

Search for more papers by this author
Sylvain Coquillat

Laboratoire d'Aérologie, Université de Toulouse, CNRS, OMP, UPS, Toulouse, France

Search for more papers by this author
First published: 16 November 2020

Abstract

Isolated breakdown process (also known as attempted leader or inverted intra‐cloud discharge) is a lightning phenomenon characterized by radio wave pulses similar to signatures of preliminary breakdown before negative cloud‐to‐ground flashes, but in this case no cloud‐to‐ground return strokes occur. We identified 128 isolated breakdown pulse trains in measurements collected in the Mediterranean by a broadband receiver (0.005–37 MHz) in 2015 and 2018. By combining these records with concurrent Lightning Mapping Array measurements of very high frequency radiation (60–66 MHz) emitted by in‐cloud discharges we investigate the development of each discharge. We identify two scenarios: Either the discharges continue to propagate almost horizontally for more than 150 ms (73%), or they quickly fade out (27%). The geo‐localized sources of the observed isolated breakdown pulse trains, together with their waveform characteristics (duration, inter‐pulse intervals, regularity, and bipolar shapes) show that both scenarios are similar to initiation processes preceding negative cloud‐to‐ground flashes.

Plain Language Summary

Visible lightning return stroke represents a well‐known manifestation of atmospheric electricity. However, it is only the last stage of a complex sequence of phenomena that starts inside an electrically charged thundercloud by a preliminary breakdown process, continues by a stepped leader that moves electrical charges into the lightning channel, neutralized eventually by a large return stroke current and followed in most cases by processes leading to subsequent strokes. All these phenomena occurring inside or below the thundercloud involve impulsive electrical currents and hence emit radio waves. Analysis of our observations of isolated breakdown radio wave pulses which are not followed by a return stroke shows that the underlying processes are similar to a usual preliminary breakdown preceding negative cloud‐to ground discharges. Nevertheless, a strong positive charge layer at the bottom of the thundercloud can force the breakdown current pulses to keep flowing inside the cloud or die out and thus prevents them from evolving into a return stroke that would move the negative charge from the cloud to the ground.

Data Availability Statement

The broadband data are available online (at http://bleska.ufa.cas.cz/ersa/storage/tar/). The SAETTA data are available online (at https://doi.org/10.17632/8cdzb27mmv.1).