HiLASE offers LIDT (Laser Induced Damage Threshold) services, thanks to unique laser sources (BIVOJ laser, 10J, 10ns, 10 Hz) under a new testing regime with big spot size and high energy density. Laser Induced Damage Threshold (LIDT) is a key parameter for the optical components of high power laser systems and their beam distribution systems. The LIDT value indicates the maximum amount of energy (power) that a surface can withstand before damage occurs.
INDUSTRIES
OPTICS – Precise determination of LIDT of optics and coatings
LASER R&D – LIDT helps to choose the right optical components
LASER MACHINE INTEGRATORS – LIDT ensures the quality of optical components in designed setups
LASER END-USERS – an accurate determination of optimal manufacturing conditions and processing windows
BENEFITS
- Test accurate damage threshold limits of various optical components and materials
- Support the development of high-power optical components
- Identify production defects of optical elements
- Test large size optical element
- Provide processing window values for laser material processing
Can be used for testing of:
- dielectric materials, amorphous or crystalline
- metals
- ceramics
- various exotic compounds and alloys
FIGURES
100 x 100 mm2– available sample surface areas
1.5 kg – available weight of samples
1030/515/343 nm wavelengths
10 ns/1.8 ps pulse durations
3x3 mm2 top-hat beam
Up to 15 mm spot size Gaussian beam
WHY WORK WITH HiLASE?
- Extensive R&D capabilities to develop and apply LIDT testing
- State-of-the-art pulsed laser systems with unprecedented intensities
- Capability to perform LIDT at truly edge conditions
- ISO class 7 clean laboratory allows measurements with unbeatable precisions
- ISO-certified or custom-designed tests with results delivered on ISO-compliant protocols
HILASE EQUIPMENT AND SERVICES
Picosecond pulsed laser |
@1030 nm, <1.8 ps, 1 kHz rep. rate, up to 100 mJ energy in a pulse |
Nanosecond pulsed laser (Bivoj laser) |
@ 1030 nm, 10 ns, 10 Hz rep. rate, up to 10 J energy in the pulse |
Experimental chamber |
Testing at vacuum down to 10-3 mBar or in the presence of non-corrosive gas pressured up to 1.4 Bar |
Samples mounting |
high-precision vacuum-compatible motorized micrometric stages with cryo-cooled sample holder |
Variable spot sizes |
from 0.4 mm to 15 mm |
Advanced on-site and ex-post samples monitoring and analysis |
1k fps 1.3 Mpix camera, beam profilers, confocal microscope |
Types of measurement |
S-on-1, R-on-1, 1-on-1, custom LIDT |
Contact
Technology transfer manager